Thermocouple

For transmission of thermoelectric voltage from measuring junction to reference junction.

Special Features on Request :
• Oil Resistance
• UV Resistance
• Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
• Heat Resistance
• Anti Termite
• Anti Rodent
• Low Smoke Zero Halogen
• Nylon Coated


Fig. 02 : Individual Screen

Note :
Conductor Shape
All construction supplied in solid (re) or circular stranded (rm)

Standard Packing
All conductor supplied in wooden drum @ 1000 m
Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²

Construction Data

No.
of
pairs
Size
1.5 mm2
Collective Screen Individual Screen
Overall
Diameter

Cable
Weight
Overall
Diameter
Cable
Weight
approx.
approx. approx. approx.
mm
kg/km
mm
kg/km
1 9.9 137 - -
2 12.8 200 14.6 314
3 14.9 244 15.5 361
4 16.7 304 16.9 425
5 18.3 389 18.5 430
6 19.7 434 21.5 530
7 21.0 477 21.5 546
9 23.5 589 25.5 689
10 25.0 655 27.5 771
12 27.0 764 30.0 905
14 29.0 886 31.5 1,042
15 30.0 967 33.5 1,135
16 30.5 1,021 35.0 1,210
18 32.5 1,116 37.5 1,330
19 33.0 1,170 37.5 1,387
20 34.0 1,266 39.5 1,566
24 37.0 1,470 46.5 1,788
30 41.0 1,808 49.5 2,176
36 45.0 2,168 54.0 2,609
40 47.5 2,380 56.0 2,859
48 51.5 2,847 63.0 3,437
50 52.5 2,953 64.5 3,567

Material & Color Code

Type EX
Material ( + )
Chromel
( - ) Constantan
Limit of Error -
(Temp. Range)
IEC 60584 Class 1
µ 1.5 °C / µ 120 mV ( -25 ~ 200 °C)
Class 2 µ 2.5 °C / µ 200 mV ( -25 ~ 200 °C)
ANSI MC - 96.1 µ 1.7 °C ( 0 ~ 200 °C )
Color Code Insulation ( + )
Purple
( - ) Red
Jacket Purple

Electrical Data

Conductor AC
Normal
Cross
Section
Nominal Value
Loop Resistance
at 20 °C
Voltage
Test
mm2
/km volt/1 min.
1.5 831 1000